Essential tool for fat processing, where we can find the highest concentration of stem cells, for liposculpture techniques and reparative surgery.
Features
Maximize
Minimize
- Available rotors for tubes (check Digtor 22 accessories).
TFT color touch screen, visible from more than 3 m.:
- Shows RPM and RCF, time, acceleration/deceleration values (PCBS) and unbalance location system (ULS).
- Speed programming in 10 RPM/ 10 xg steps
- Real RCF values on screen based on accessories configuration.
- Count up/down from “0” or at “set RPM/RCF” for test reproducibility.
- Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
- Timer from 1 sec. to 99 hours programmable in 1 sec. steps and hold position.
- PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation.
- ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off.
- Start delay: To program the time at which the cycle is to begin.
- Linked program: Permits the linking of up to 8 consecutive programmes without the need of user intervention.
- 40 programmable memories, with protection under password.
- Several acoustic and visual messages showing the user the situation of the device.
User friendliness
Maximize
Minimize
- Microprocessor controlled. PC connection.
- Induction motor maintenance free (brushless).
- Rotors and adapters list on memory.
- Noise level: below 60 dB.
- Start, stop, open lid and short spin with adjustable speed buttons.
- Option of free/locked adjustment of RPM/ RCF along the run.
- Automatic open lid, programmable.
- Last values remain in memory.
- Automatic rotor recognition. Over-speed protection.
Safety
Maximize
Minimize
- Lid provided with security systems:
– Automatic lid lock system, motorized with double lock.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
- Unbalance detection and switch off.
- Protection safety ring between the centrifugation chamber and the housing.
- Chamber of centrifugation in stainless steel (easy cleaning).
- Rotors and adapters autoclavable, easy to install by the user.
- Forced ventilation to reduce temperature increasing.
- Automatic disconnection for energy saving up to 8 h., with deactivation option.
Standards and Directives
Maximize
Minimize
EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU.
Standards: EN 61010-1,EN 61010-2-101, EN 61010-2-020, EN 61326-2-6,EN 61326-1.
Versions
Maximize
Minimize
Code | Dimensions (mm) (w x d x h) | Net weight (Kg) | Voltage (V) | Frequency (Hz) | Consumption (W) |
---|---|---|---|---|---|
CE 204 | 530x640x400 | 73 | 220-230 | 50-60 | 460 |
CE 205 | 530x640x400 | 73 | 110-120 | 50-60 | 460 |