With capacity for 4 tubes of 8”, 6”, trace and 28 “finger” tubes. Versatile and effective is the better option out of all the centrifuges for oil applications.
Check here the equipment’s applications and standards.
Features
Maximize
Minimize
Designed for oil/petrol applications according the standards: ASTM D 91, D96, D 893, D 1796, D2273, D2709, D 2711, D 4007, D 5546, API 2542, API 2548, BS 4385, ISO 3734, ISO 9030, IP75, IP 359, NF M07-020, DIN 51793. Fits Babcock bottles.
Tubes upright on rest.
Gas Release System (GRS): Gas release system (optional); pre-installation included.
TFT color touch screen, visible from more than 3 m.:
- Shows RPM and RCF, time, temperature, acceleration/deceleration values (PCBS and unbalance location system (ULS).
- Speed programming in 10 RPM/10 xg steps.
- Real RCF values on screen based on accessories configuration.
- Count up/down from “0” or at “set RPM/RCF” for test reproducibility.
- Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
- Timer from 1 sec. to 99 hours programmable in 1 sec. steps and hold position.
- PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation.
- ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off.
- Start delay para programar el momento en el que ha de comenzar el ciclo.
- Linked program: enlaza hasta 8 programas consecutivos sin intervención del usuario.
- 100 programmable memories, with protection under password.
- Several acoustic and visual messages warning the user the device situation.
User friendliness
Maximize
Minimize
- Microprocessor controlled. PC connection.
- Induction motor maintenance free (brushless).
- Rotors and adapters list in memory.
- Noise level: below 60 dB.
- Start, stop, open lid and short spin with adjustable speed buttons.
- Option of free/locked adjustment of RPM/ RCF along the run.
- Last values remain in memory.
- Automatic rotor recognition. Over-speed protection.
Safety
Maximize
Minimize
- Lid provided with security systems:
– Automatic lid lock system, motorized with double lock.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
- Unbalance detection and switch off.
- Protection safety ring between the centrifugation chamber and the housing.
- Chamber of centrifugation in stainless steel (easy cleaning).
- Rotors and adapters autoclavable, easy to install by the user.
- Automatic disconnection for energy saving up to 8 h.
Heating
Maximize
Minimize
- Preheating program with rotor spinning and selectable temperature. It allows keeping the chamber at working temperature before starting the process.
- Regulation of the room temperature +5°C (41°F) to 80°C (176°F) in 1°C/1°F steps Programmable in °C o °F.
- Temperature sensor inside the chamber. Overheating protection.
- Internally isolated avoiding heat loss.
Standards and Directives
Maximize
Minimize
EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU.
Standards: EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-2-6, EN 61326-1, EN 61010-2-010.
Versions
Maximize
Minimize
Code | Dimensions (mm) (w x d x h) | Net weight (Kg) | Voltage (V) | Frequency (Hz) | Consumption (W) |
---|---|---|---|---|---|
CE 238 | 530x640x400 | 76 | 220-230 | 50-60 | 1260 |
CE 239 | 530x640x400 | 76 | 110-120 | 50-60 | 1220 |