One of the best options when high speed and different tube formats are required. This refrigerated microcentrifuge, which has a wide range of rotors for a cooled centrifuge, can work with conical type tubes from 0,2 ml. to 15 ml. Dynamic cooling equipment keeps the desired temperature, reaching it in a short period of time and maintaining it stable throughout the whole cycle, regardless of the operation speed. Customisation of equipment options through the software enables you to adapt the work cycles to the process as well as the user preferences, thus optimising performance in your laboratory.
For Ortoalresa, the Biocen 22 R centrifuge is the culmination of its know-how in centrifugation, materialised for the user in a robust, versatile and efficient piece of equipment that integrates perfectly into any lab, highlighting its application in research and biotechnology.
Features
Maximize
Minimize
LCD screen:
- Shows RPM and RCF, time, temperature and acceleration/deceleration (PCBS).
- Speed programming in 10 RPM/ 10 xg steps.
- Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
- Timer: from 5 sec. to 99 minutes or from 1 min. to 99 hours and indefinite time.
- PCBS: Progressive controlled braking system up to 175 selectable ramps that prevents sample homogenization after separation.
- 16 programmable memories.
- Several acoustic and visual messages showing the user the situation of the device.
Easy to use
Maximize
Minimize
- Microprocessor controlled.
- Induction motor maintenance free (brushless).
- Rotors list in memory.
- Noise level: below 65 dB.
- Start, stop, open lid and short spin with adjustable speed buttons.
- Option of free/locked adjustment of RPM/ RCF along the run.
- Low height for easy access.
- Last values remain in memory.
- Automatic rotor recognition. Over-speed protection.
Safety
Maximize
Minimize
- Lid provided with security systems:
– Automatic lid lock system, motorized with double lock.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
- Ergonomic design that allows close the lid effortless.
- Unbalance detection and switch off.
- Protection safety ring between the centrifugation chamber and the housing.
- Chamber of centrifugation in stainless steel (easy cleaning).
- Rotors can be removed with the lid closed. Hermetic lids.
- Rotors and adapters autoclavable, easy to install by the user.
- Automatic disconnection for energy saving up to 8 h.
Cooling
Maximize
Minimize
- Maintains the refrigeration after the centrifugation process.
- Precooling program with rotor spinning and selectable temperature.
- Guarantees 4 °C at maximum RPM.
- Temperature range from -20°C (-4°F) to 40°C (104°F) in 1°C steps.
- Temperature sensor inside the chamber.
- Gas R 449A HFO (CFC free).
Standards and Directives
Maximize
Minimize
EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC.
Regulation n°: (EC) 1005/2009, (EU) 517/2014.
Standards: EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-2-6, EN 61326-1.
Versions
Maximize
Minimize
Code | Dimensions (mm) (w x d x h) | Net weight (Kg) | Voltage (V) | Frequency (Hz) | Consumption (W) |
---|---|---|---|---|---|
CE 148 | 270x650x280 | 41 | 220-230 | 50 | 540 |
CE 149 | 270x650x280 | 41 | 110-120 | 60 | 700 |